Bradley Smoker Outdoor Shower HN 400 User Manual

Installation  
Instructions  
HN-400  
Barrier-Free Column Shower  
Table of Contents  
Pre-Installation Information . . . . . . . . . . . . . . . .2  
HN-200 Column Shower Components  
and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .2  
Installation Instructions  
Type A Column Shower . . . . . . . . . . . . . . . . . .3  
Supplies from Below/Vent Off Line  
Type B Column Shower Installation . . . . . . . .4  
Supplies from Above/Vent Through Column  
Type H Column Shower Installation . . . . . . . .5  
Supplies from Below/Vent Through Column  
Type O Column Shower Installation . . . . . . . .6  
Supplies from Above/Vent Off Line  
Optional Shroud Installation . . . . . . . . . . . . . . . .7  
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . .9  
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
IMPORTANT:  
Before beginning installation, all supply, drain and waste  
piping to the shower must be completed according to the  
rough-ins received with the drain assembly.  
Check the local codes and ordinances in your area for  
proper location and connection requirements. Conformity  
to local codes is the responsibility of the installer.  
Read and save this installation manual, which contains  
maintenance and repair information, for future reference.  
P.O. Box 309, Menomonee Falls, WI 53052-0309  
TEL: 1-800-BRADLEY FAX: (262) 251-5817  
215-781; Rev. D; EN 03-310  
© 2003 Bradley Corporation  
Page 1 of 9  
12-16-2003  
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Installation Instructions for Type A HN-400 Column Shower  
Step 1: Install column shower components  
NOTE: Flush supply lines before making connections.  
1. Remove the five bolts that secure the disposable washer to  
the drain and lift the disposable washer off.  
2. Bolt the column shower to the drain with the five bolts  
(removed in procedure #1) and oval washers provided (see  
Figure 1).  
(5) 5/16"-18  
HEX-HEAD  
BOLTS  
160-092  
Step 2: Connect water supply  
1. Remove the two 1/4"-20 screws from the access panel on  
the lower body of the column shower and lift the panel off.  
2. Through the access opening, connect water supplies to the  
shower’s 3/4" copper tubing as shown in Figure 2 (piping  
supplied by installer).  
(5) WASHERS  
142-034  
3. Turn on water to the shower and test for leaks and adequate  
Figure 1  
water flow.  
4. Replace the access panel onto the shower with 1/4"-20 screws provided.  
NOTE: For column shower drains with a dome grate drain, install the two halves of the grate with  
the screws provided after the column installation is complete.  
Figure 2  
Supplies from Below/Vent Off Line  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
12-16-2003  
3
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Installation Instructions for Type B HN-400 Column Shower  
Step 1: Install column shower components  
NOTE: Flush supply lines before making connections.  
1. Remove the five bolts that secure the disposable washer to  
the drain and lift the washer off.  
2. Loosen the screw(s) securing the shower cover and lift the  
cover off. DO NOT remove the screw(s)!  
(5) 5/16"-18  
HEX-HEAD  
BOLTS  
3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.  
160-092  
NOTE: Make sure that vent pipe does not snag internal wiring or  
come in contact with electronic components.  
4. Position the shower over the drain and screw the 2" NPT  
vent pipe into the vent connection (see Figure 4).  
5. Bolt the shower to the drain with the five bolts (removed in  
procedure #1) and oval washers provided (see Figure 1).  
(5) WASHERS  
142-034  
Step 2: Connect water supply  
Figure 3  
1. Drop the supplies to the top of the column shower.  
2. Slide the column cover up the vent and supply piping.  
NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first,  
and then slide the column cover up (see page 7 for shroud installation).  
3. Make supply connections. Supply connection must be made inside the top of the shower so that  
there is no interference with the piping and the column cover.  
4. Turn on water to the shower and test for leaks and adequate water flow.  
5. Secure the column cover with the screws provided.  
NOTE: For column shower drains with a dome grate drain, install the two halves of grate with the  
screws provided after column installation is complete.  
Supplies from Above/Vent Through Column  
Figure 4  
4
12-16-2003  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Installation Instructions for Type H HN-400 Column Shower  
Step 1: Install column shower components  
NOTE: Flush supply lines before making connections.  
1. Remove the five bolts that secure the disposable washer to  
the drain and lift the washer off.  
2. Loosen the screw(s) securing the shower’s cover and lift the  
cover off. DO NOT remove the screw(s)!  
(5) 5/16"-18  
HEX-HEAD  
BOLTS  
3. Insert a 2" NPT vent pipe (supplied by installer) into the shower.  
160-092  
NOTE: Make sure that the vent pipe does not snag internal wiring  
or come in contact with the electronic components.  
4. Position the shower over the drain and screw the 2" NPT vent  
pipe into the vent connection (see Figure 6).  
5. Bolt the shower to the drain with the five bolts (removed in  
procedure #1) and oval washers provided (see Figure 5).  
(5) WASHERS  
142-034  
Step 2: Connect water supply  
Figure 5  
1. Remove the two 1/4"-20 screws from access panel on lower  
body of column shower and lift panel off.  
2. Through access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in  
Figure 6 (piping supplied by installer).  
3. Slide column cover over vent.  
NOTE: If you are installing a column shroud, slide the slip ring up the vent and supply piping first,  
and then slide column cover up (see page 7 for shroud installation).  
4. Turn on water to the shower and test for leaks and adequate water flow.  
5. Replace access panel onto shower with the 1/4"-20 screws provided.  
NOTE: For column shower drains with a dome grate, install the two halves of grate with the screws  
provided after the column installation is complete.  
Supplies from Below/Vent Through Column  
Figure 6  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
12-16-2003  
5
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Installation Instructions for Type O HN-400 Column Shower  
Step 1: Install column shower components  
NOTE: Flush supply lines before making connections.  
1. Remove the five bolts that secure the disposable washer to  
the drain and lift the washer off.  
(5) 5/16"-18  
HEX-HEAD  
BOLTS  
2. Bolt the shower to the drain with the five bolts (removed in  
procedure #1) and oval washers provided (see Figure 7).  
160-092  
3. Loosen the screw(s) securing the shower’s cover and lift the  
cover off. DO NOT remove the screw(s)!  
Step 2: Connect water supply  
1. Drop the supplies to the top of the column shower.  
2. Slide the column cover up the vent and supply piping.  
(5) WASHERS  
142-034  
NOTE: If you are installing a column shroud, slide the slip ring  
up the vent and supply piping first, and then slide the column  
cover up (see page 7 for shroud installation).  
Figure 7  
3. Make the supply connections. The supply connection must be  
made inside the top of the shower so that there is no interference with the piping and the column  
cover.  
4. Turn water to the shower on and test for leaks and adequate water flow.  
5. Secure the column cover with the screws provided.  
NOTE: For column shower drains with a dome grate, install the two halves of the grate with the  
screws provided after the column installation is complete.  
Supplies from Above/Vent Off Line  
Figure 8  
6
12-16-2003  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Installation Instructions for Optional  
Column Shower Shroud  
NOTE: The column shower must be installed before  
the shroud. The shroud clips and knock-outs in the  
column cover must also be prepared. Before making  
the supply connections, slide the shroud slip ring up  
the vent and supply piping.  
SLIP RING  
S57-020A (12" LONG)  
S57-141 (7" LONG)  
(SLIDES INSIDE SHROUD -  
FASTEN TO CEILING WITH  
5/16" SCREWS SUPPLIED  
BY INSTALLER)  
IMPORTANT: If the shroud is longer than 48"  
(it has a welded seam rather than a snap  
together hem) it must also be slid up the vent  
and supply piping.  
BOTTOM OF  
SLIP RING  
If the supply connections are completed prior to the  
shroud installation, the supplies will have to be dis-  
connected in order to slide the slip ring (and shroud if  
over 48" long) over the vent and piping.  
Step 3: Preparing the Column Cover  
1. Remove the column cover from the top of the  
shower by loosening the screw(s) that secures the  
column cover retainer.  
SHROUD  
(0-48" LENGTHS  
HAVE HEMMED EDGE)  
2. Carefully remove the necessary knock-outs from  
the cover (see Figure 11).  
(54"-72" LENGTHS  
HAVE WELDED SEAM)  
3. Insert the three shroud clips into the locations  
shown in Figure 11. Snap the clips in place using  
a flat blade screwdriver.  
4. Reassemble the cover on shower and proceed  
with remainder of installation.  
SCREW  
160-400  
Step 4: Complete the Installation  
1. Make sure the slip ring (and shroud if required)  
is in place over the vent and supply piping.  
2. Fasten the slip ring to the ceiling with five 5/16"  
diameter screws (supplied by installer) (see  
Figure 10 for screw location dimensions).  
3. Bring the shroud seam around the vent and sup-  
ply piping and slide the shroud together (0-48"  
long shrouds only). Fasten hem together using  
the supplied #6-32 screws.  
4. With the column cover in place and the supply  
connections made, lower the shroud and fasten to  
the column cover with the #10-24 screws  
provided (see Figures 9 and 11).  
Figure 9  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
12-16-2003  
7
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Installation Instructions .....continued  
(5) 3/8" DIA.  
EQUALLY SPACED  
HOLES  
7-3/8" DIA  
BOLT CIRCLE  
6-3/8" DIA  
Slip Ring Bolt Pattern  
Figure 10  
KNOCK-OUTS  
SHROUD CLIP  
#10-24 x 1/2" SCREW  
160-245 (QTY. 3)  
159-413  
(QTY. 3)  
KNOCK-OUT  
#10-24 x 3/4" SCREW  
160-142  
COLUMN COVER  
107-062A - 2-5 PERSON  
107-074A - 6 PERSON  
RETAINER-COLUMN COVER  
132-049  
107-529 - 6 PERSON WITH THERMOBLENDER  
107-530 - 2-5 PERSON WITH THERMOBLENDER  
Figure 11  
8
12-16-2003  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
 
Barrier-Free Column Shower  
HN-400  
Installation Instructions  
Cleaning Instructions  
IMPORTANT: Cleanliness is of utmost importance. Do not permit salty solutions to  
evaporate and dry on stainless steel. Never use ordinary steel wool or  
steel brushes on stainless steel. Always use stainless steel wool or  
stainless steel brushes.  
1. Remove ordinary deposits of dirt and grease with soap and water. Whenever possible, the metal  
should be thoroughly rinsed and dried after washing.  
2. Use stainless steel polishing powder to get rid of tightly adhering deposits.  
3. Look for the source of the rust in some iron or steel not actually a part of the stainless steel struc-  
ture. Sometimes the appearance of rust streaks on stainless steel leads to the belief that the stain-  
less steel is rusting. A steel nail or screw may be the cause of the trouble.  
4. If the showerhead delivers an uneven spray, remove the showerhead from the unit, disassemble,  
and remove foreign matter.  
5. Reassemble showerhead and reinstall into unit.  
HN-400 Column Shower Warranty  
Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in  
material and workmanship under normal use and service upon the following terms and conditions:  
1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the  
purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within  
the limitations of this warranty.  
2. The period during which Column Shower components are warranted is one (1) year, measured from the  
date of our invoice.  
3. This warranty does not cover installation or any other labor charges and does not apply to any units  
which have been damaged by accident, abuse, improper installation or improper maintenance.  
4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of  
the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation  
shall not otherwise be liable under any circumstances for incidental, consequential or indirect damages  
caused by defects in the repair or replacement thereof.  
5. This warranty extends only to commercial and institutional purchasers and does not extend to any others,  
including consumer customers of commercial and institutional purchasers.  
6. This warranty is in lieu of all other warranties, express or implied, including any implied warranty of  
merchantability or fitness for a particular purpose or otherwise.  
Bradley Corporation • 215-781 Rev. D; EN 03-310  
12-16-2003  
9
 

Black Decker Saw 606989 00 User Manual
Bolens Lawn Mower 660 Thru 679 User Manual
Bosch Appliances Washer WFL 2060UC User Manual
Boss Audio Systems Car Stereo System BV9964B User Manual
Braun Electric Shaver Series7 User Manual
Breville Popcorn Poppers PCM40 User Manual
Canon Film Camera EF M User Manual
Carcomm Cell Phone Accessories CMPC 15 HTC Himalaya Alpine Qtek 2020 2020i User Manual
Centro Gas Grill 07012009 User Manual
Chief Manufacturing Indoor Furnishings CM2 User Manual