Broan Vacuum Cleaner VX12000C User Manual

CENTRAL VACUUM POWER UNIT  
AB0001  
For Power Unit  
Broan models VX3000C, VX6000C, VX12000C  
HOMEOWNER'S OPERATING INSTRUCTIONS  
30042323 rev. C  
 
page 3  
VACUUM POWER CONTROL EMPTYING THE  
The wand ends of the deluxe hoses are equipped with a control  
DEBRIS PAIL  
ring to regulate suction. The control ring covers a “bleeder”  
Your power unit has a permanent filter that is self cleaning  
under normal conditions. The filter protects the motor and  
stops small dirt particles from escaping to the outside of the  
power unit. The filter cleans itself by moving up when the  
power unit starts, and dropping down when the unit is turned  
off. The filter can be removed by means of a pull-tab for  
cleaning if desired. Be sure to reinstall properly. Correct  
placement is critical to insure proper protection for the motor.  
hole. Open the hole to reduce the suction for cleaning  
draperies, small rugs, and other light fabrics. Some very thick,  
plush carpets with high density yarns also require reduced  
suction to make the nozzle easier to push. Be sure to close the  
control ring completely over the hole to produce the maximum  
power required for most other cleaning tasks.  
WHEN TO EMPTY THE  
DEBRIS PAIL  
1. Release both carry handles on side of the unit by pulling  
out and then pushing up. (FIGURE 14). Holding the pail by  
the handles, lower it from unit (FIGURE 15).  
Broan model VX3000C has a single indicator light that  
remains green. The level of pail fill for this model can be  
determined by either viewing through the window on the pail or  
releasing the carry handles and checking the level of debris in  
the pail.  
2. Carry pail to trash receptacle and empty.  
3. Reattach pail using handles.  
4. Push Reset button on control panel. Light on control panel  
will change to green on Broan models VX6000C  
& VX12000C.  
Broan models VX6000C & VX12000C have the LED indicator  
that shows the status of the level of debris in the pail. The first  
three lights remain green as pail fills. The fourth light is amber  
and will come on to alert you that the pail is nearly full. When  
the fifth light turns red it is time to empty the pail (see  
CONTROL PANEL DIAGRAM A).  
CONTROL PANEL DIAGRAM A  
Broan VX3000C  
FIGURE 14  
FIGURE 15  
Manually check  
pail to determine  
fill level.  
Utility valve (Circled in FIGURE 15), next to power unit, can be  
used to service area around where power unit is installed.  
Green Only  
CLEANING THE INTERNAL FILTER  
When emptying the debris  
pail, it is a good idea to also  
clear any dust and dirt that  
may have accumulated on  
the internal filter media. To  
do this, simply open the  
direct door, reach in and tap  
the top of the internal filter  
(FIGURE 16). This will  
release any loose debris into  
the pail. You may empty the  
pail again at this point but it  
is not necessary as any  
Broan VX6000C &  
VX12000C  
Timed pail full  
indicator  
Green Amber Red Reset  
amounts of dirt and dust will  
FIGURE 16  
be minimal. Close the door.  
 
page 4  
TROUBLESHOOTING GUIDE  
Read before calling Service Center.  
Possible Remedy  
Possible Cause  
Trouble  
1a.Empty debris pail as described on page 3.  
1a.Debris pail is completely full.  
1. Loss or  
decrease of  
vacuum occurs.  
1b.Insert handle end of hose into utility valve at  
power unit. Turn unit on. This will reverse normal  
air flow through the hose and dislodge any clogs.  
1b.Obstruction in the hose. A blockage in the hose  
can be determined by inserting the hose into any  
wall inlet and, while power unit is running, check  
each additional inlet for normal suction by holding  
the palm of your hand over the open inlet. If normal  
suction is felt at all other inlets, insert the hose  
into a second inlet. If the blockage still exists it is  
located in the hose. However, if the blockage  
does not occur when the hose is changed, the  
blockage is probably located in the tubing system  
leading to the original inlet.  
1c.Insert hose end into any inlet with power unit  
running, place the palm of your hand over the  
opposite end of the hose. When you can feel the  
suction increase, hold your hand over the hose  
end for a few seconds and then quickly remove  
your hand. This procedure repeated several  
times should clear the obstruction. If the blockage  
is not cleared, contact your nearest Service Center.  
1c.Obstruction in the tubing system inside  
the walls.  
1d.Check all wall inlet covers to be sure they are  
1d.Wall inlet cover not properly sealed.  
closed and sealed tightly.  
1e.Inspect and remove any blockages.  
2a.Replace defective wall inlet.  
1e.Exhaust tubing or vent clogged.  
2a.Defective inlet. Check other wall inlets.  
2. Power unit does  
not start, or  
2b.Turn unit off for 20 minutes then plug unit back in.  
If unit does not start, look for the tripped circuit  
breaker behind the unit, a white button has  
popped up, push it back to reset it. If circuit  
breaker trips again, unplug your unit and contact  
your local Service Center.  
2b.Thermoprotector has been activated OR there is  
shuts off during  
normal operation  
with no LED  
showing red or  
illuminated.  
a tripped circuit breaker on the unit.  
2c.Replace fuse or reset circuit breaker on house  
2c.Blown fuse or tripped circuit breaker on house  
electrical panel.  
electrical panel.  
2d.Replace hose as required.  
2d.Defective hose.  
2e.1) Push Reset button while unit is engaged OR  
2e.Microprocessor lockup.  
2) Unplug unit completely for 60 seconds.  
NOTE: This apply only to Broan VX6000C  
& VX12000C.  
2f. Contact your local Service Center.  
2f. Low line voltage.  
2g.Empty debris pail as described in page 3.  
2g.Debris pail full sensing has been activated.  
 
page 5  
TROUBLESHOOTING GUIDE (cont’d)  
Trouble  
Possible Cause  
Possible Remedy  
3. Power unit fails  
to stop when the  
hose is removed.  
3a.An electrical short has occurred somewhere  
3a.A complete check of all wall inlets and power  
unit low voltage control lead connections. Turn  
system off by removing fuse or tripping circuit  
breaker at house fuse box.  
in the system.  
4. Power unit shuts 4a.Debris pail and/or direct door not fully closed  
4a.Check and close direct door and make sure debris  
off during normal  
operation, lights on  
unit, wall valve and  
hose are all red.  
or attached.  
pail handles are fully locked.  
5. On Broan VX6000C 5a.Two or more hoses may be plugged into  
5a.Check all other wall inlets, utility valve at power unit  
& VX12000C units  
only, all lights on  
control panel flash  
when unit is first  
plugged in.  
the system.  
and sweep inlet valve.  
INTERNAL WIRING DIAGRAM  
WIRING DIAGRAM VX3000C, VX6000C  
WIRING DIAGRAM VX12000C  
RED  
WHITE  
BLACK  
BLACK  
GREEN  
GREEN  
240 VOLTS  
GREEN  
GREEN  
GREEN  
120 VOLTS  
CONTROL  
BOARD  
THERMAL  
THERMAL  
PROTECTOR  
CONTROL  
BOARD  
PROTECTOR  
BLACK  
BLACK  
WHITE  
BLACK  
BLACK  
MOTOR  
MOTOR  
RED  
THERMAL  
PROTECTOR  
BLACK  
MOTOR  
AE0006A  
CONTROL  
AE0005A  
CONTROL  
 
page 6  
GROUNDING INSTRUCTIONS  
WIRING  
This section refers to Figure 17 and 18.  
Grounding Instructions – This appliance must be grounded. If it should malfunction or break down, grounding provides a path of  
least resistance for electric current, to reduce the risk of electric shock. This appliance is equipped with a cord  
having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly  
installed and grounded in accordance with all local codes and ordinances.  
Danger – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified  
electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with  
the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.  
This appliance is for use on a standard 120VAC, individual 20-amp branch circuit with a NEMA 5-20R receptacle for Broan models  
VX3000C & VX6000C. For Broan model VX12000C, a nominal 240VAC, individual 20-amp branch circuit with NEMA 6-20R receptacle  
is required. Make sure that the appliance is connected to an outlet and has a grounding attachment plug that looks like the plug  
shown in either Figure 17 or 18 depending on the model. No adapter should be used with this appliance.  
Broan VX3000C & VX6000C  
NOTE: INLET LEADS TO BE CONNECTED TO POWER UNIT  
TERMINALS USING CRIMP CONNECTORS  
AND LOW VOLTAGE WIRE HARNESS  
NORTH AMERICA  
LOW VOLTAGE  
AC ELECTRIC  
WIRE HARNESS  
OUTLET  
LOW VOLTAGE WIRE  
120 VOLT GROUNDED  
OUTLET BOX  
CRIMP CONNECTORS  
GROUND PIN  
NEMA 5-20R  
INLET  
LEADS  
POWER  
CORD  
POWER  
UNIT  
MODEL V133 18/2 WIRE  
TO  
OTHER  
INLETS  
AE0009A  
FIGURE 17  
Broan VX12000C  
NOTE: INLET LEADS TO BE CONNECTED TO POWER UNIT  
TERMINALS USING CRIMP CONNECTORS  
AND LOW VOLTAGE WIRE HARNESS  
LOW VOLTAGE  
WIRE HARNESS  
NORTH AMERICA  
AC ELECTRIC  
OUTLET  
LOW VOLTAGE WIRE  
240 VOLT GROUNDED  
OUTLET BOX  
CRIMP CONNECTORS  
GROUND PIN  
INLET  
LEADS  
POWER  
CORD  
NEMA 6-20R  
POWER  
UNIT  
MODEL V133 18/2 WIRE  
TO  
OTHER  
INLETS  
FIGURE 18  
AE0010A  
 
page 7  
SERVICE PARTS LIST (BROAN MODELS VX3000C, VX6000C & VX12000C)  
9
8
4
5
10  
2
6
7
3
1
Key No. Part No.  
Description  
VX3000C  
VX6000C VX12000C  
10941189 Pail assembly VS  
10941191 Pail assembly TS  
10941192 Door assembly  
X
1
2
3
X
X
X
X
X
X
X
X
X
10941199 Latch kit (with screws)  
10941232 VS PCB’s assembly (including mother, daughter and screws)*  
10941233 TS1 PCB’s assembly (including mother, daughter and screws)*  
10941195 TS2 Motherboard/Daughterboard S/A incl. screws*  
10941235 VS motor with motor harness, fuse with fuse harness, circuit breaker*  
10941236 TS1 motor with motor harness, fuse with fuse harness, circuit breaker*  
10941231 TS2 motor with motor harness, fuse harness, circuit breaker*  
30100528 Pail gasket TS  
30100527 Pail gasket VS  
30010272 Cyclonic filter VS  
30010270 Cyclonic filter TS  
10941217 Motor Chamber VS with foam and logo*  
4
5
X
X
X
X
X
X
X
6
7
8
X
X
X
X
X
X
X
X
X
10941218 Motor Chamber TS with foam and logo*  
10941211 Top cap VS with logo  
9
10941213 Top cap TS with logo  
X
X
X
X
10941201 Motor brush 120V + installation document*  
10941202 Motor brush 240V + installation document*  
10  
NOTE: Order service parts by “Part No.” - not by “Key No.”  
*This part MUST be removed and installed by a qualified technician.  
 
BROAN MODELS VX3000C, VX6000C, VX12000C  
page 8  
BROAN-NUTONE CANADA INC.  
CENTRAL VACUUM POWER UNIT  
LIMITED LIFETIME WARRANTY  
Broan-NuTone Canada warrants to the original consumer purchaser that its central vacuum power unit will be free from defects in materials and workmanship for as  
long as you own your home in which it was originally installed with the exception of the motor brushes which will be warranted for 5 years. THERE ARE NO OTHER  
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE.  
During these time periods, Broan-NuTone Canada will repair the power unit or part without charge, which is found to be defective under normal use and service.  
THIS WARRANTY DOES NOT APPLY TO THE INSTALLATION OR THE PARTS USED IN THE INSTALLED TUBING SYSTEM. All central vacuum hoses, electric or  
air-driven brushes, filters, attachments and accessories are warranted for one (1) year from the original purchase date with the exception to consumables such as light bulbs  
and belts.  
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper  
maintenance or repair (other than by Broan-NuTone Canada or an authorized representative), faulty installation or installation contrary to recommended installation  
instructions.  
The duration of any implied warranty is limited to the period as specified for the express warranty.  
BROAN- NUTONE CANADA’S OBLIGATION TO REPAIR SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. DO NOT  
RETURN YOUR UNIT TO PLACE OF PURCHASE. CALL TOLL FREE 1-888-882-7626 FOR THE NAME OF AN AUTHORIZED REPRESENTATIVE IN YOUR AREA.  
THIS REPRESENTATIVE WILL REPAIR YOUR UNIT AT YOUR SITE OF INSTALLATION. BROAN-NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL,  
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. This warranty supersedes all  
prior warranties.  
To qualify for warranty service, you must notify Broan-NuTone Canada at the address or telephone number stated below. We will then forward you the authorized service  
depot in your area. You will be required to present evidence of the original purchase date.  
Date of Installation  
Builder or Installer  
Model Number and Product Description  
IF YOU NEED ASSISTANCE OR SERVICE:  
For the location of your nearest Broan-NuTone Canada Inc. dealer:  
Dial Toll Free: 1-888-882-7626  
Please be prepared to provide:  
Product model number ● Date and proof of purchase ● The nature of the difficulty  
Broan-NuTone Canada Inc.  
1140 Tristar Drive, Mississauga, Ontario L5T 1H9  
Product specifications subject to change without notice.  
Printed in Canada.  
 

BenQ Computer Monitor RL2450H RL2450HT User Manual
BenQ Projector PB2120 User Manual
Black Decker Can Opener KEC500 User Manual
Black Decker Vacuum Cleaner VE100K User Manual
Cadillac Mobility Scooter CTS V Series User Manual
Cal Flame Charcoal Grill LTR20081044 User Manual
Canon Digital Camera 3000V User Manual
Cardinal Gates Safety Gate CP30 User Manual
Chaney Instrument Thermometer 415 User Manual
Chip PC Computer Hardware CDC01927 User Manual