CCA5/7 Extractors
Manual for Installation, Use and Maintenance
Customer Care Department • The
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY
Using your Extractor
For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for
approximately 15 minutes after the end of cooking.
A - Light switch
B - Power indicator light
C - Power switch
A
B
C
A1 A2
C1 C3
C2 C4
Fig. 1
To switch the extractor light on or off
Slide the light switch to position A1 for off, or A2 for on.
•
To switch on the extractor, or change the motor speed
Slide the power switch to the position required dependent on the speed you require.
•
To switch the extractor off
Slide the power switch to position C1 for off.
•
Care and Maintenance
IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST
SWITCHING OFF THE ELECTRICITY SUPPLY.
Cleaning
You should use a non-abrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase
the control panel markings.
You can clean you extractor effectively by simply using a dilute solution of water and mild detergent and drying to a
shine with a clean cloth, for example the CDA E-Cloth.
Cleaning the grease filter
The grease filter should be kept clean to minimize the risk of fire.
At least once a month you should remove and clean the grease filter with hot soapy water.
To remove the grease filter, follow the steps below:
1. Unfasten the sliding brackets on either side of the cover panel and the cover panel will hinge open.
2. Remove the filter retaining wires from the cover panel.
3. Remove the grease filter and wash by hand in a lukewarm solution of water and mild detergent. Once clean
squeeze the grease filter but DO NOT wring it out. Clean the filter holder using a dilute solution of water
and mild detergent or with a damp cloth. Allow the grease filter to dry completely before reassembling
the extractor.
4. Replace the grill panel and refasten the sliding brackets.
5. Replace the grease filter in the cover panel and reattach the filter retaining wires.
Please note:
The extractor must not be used without the grease filter in place.
Changing the charcoal filter
To ensure best performance of your extractor, you should replace
the charcoal filters every four to six months, depending on use.
Please note the charcoal filter cannot be washed. To attach a new
charcoal filter, follow the steps below.
1. Unfasten the sliding brackets on either side of the cover
panel and the cover panel will hinge open.
2. Place the charcoal filter on the centre of the motor
support, and once firmly located turn the charcoal filter
clockwise 90
˚
until you hear a click which locks the charcoal
filter into position.
Replace the cover panel and refasten the sliding brackets.
Fig. 2
Changing the Light
IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST
SWITCHING OFF THE ELECTRICITY SUPPLY.
DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO
COOL BEFORE REMOVING IT.
1. Unfasten the sliding brackets on either side of the cover panel and the cover panel will hinge open.
2. Remove the faulty light bulb and replace with a light bulb no more powerful than that specified on the
rating plate.
3. Replace the cover panel and refasten the sliding brackets.
Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights.
The light is designed for use during cooking and not for general room illumination. Extended use of the light can
reduce the lifespan of the bulb.
Bulb replacement is not covered by the guarantee.
Only use bulbs recommended for your extractor. Do not fit bulbs of a higher power rating. Bulbs of a lower power
rating may be adequate for use, generally last longer, and use less energy.
Spare bulbs are available from CDA Customer Care or from your local DIY shop.
Mains Electricity Connection
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED
WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE.
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
DOUBLE POLE SWITCHED
The wires in the mains lead of this appliance are coloured in accordance with the
FUSED SPUR OUTLET
following code:
BLUE = NEUTRAL, BROWN = LIVE.
As the colours of the wires in the mains lead for the appliance may not correspond
with the coloured markings identifying the terminals connecting to the fused spur,
proceed as follows:
•
•
The wire which is coloured blue must be connected to the terminal marked N
(Neutral), or coloured black.
The wire which is coloured brown must be connected to the terminal marked
L (Live), or coloured red.
USE A 3 AMP FUSE
NOTE: USE A 3A FUSE
Assembly and electrical connection should be carried out by competent personnel.
When installing this product we recommend you seek the help of another individual.
IMPORTANT: THIS APPLIANCE IS A CLASS II APPLIANCE (DOUBLE INSULATED) AND IS NOT INTENDED TO
BE EARTHED. DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR.
Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the
extractor from the mains electrical supply after installation.
This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur
and is intended to be protected by a 3A fuse. The use of a 13A fuse can cause damage to the internal wiring in the event
of a fault, and may also invalidate the warranty.
Electrical Information
Mains electrical voltage: 230 – 240Vac.
Total rated power consumption CCA5: 150W.
Total rated power consumption CCA7: 300W.
Troubleshooting
Please note:
Your extractor is equipped with a motor protection device that will switch off the motor to prevent damage from
overheating. This may happen during cooking when most or all of the zones/burners are being used simultaneously.
This is normal, and the extractor will work again once the motor has cooled sufficiently.
If your extractor is not working:
1. Check that the mains supply has not been switched off.
2. Check that the fuse in the spur has not blown.
Contact CDA Customer Care
A : Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY
Installation
When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must
exceed 600mm (650mm is recommended).
When the extractor is to be installed above a gas hob, the minimum distance between the hob and extractor must
exceed 700mm (750mm is recommended).
If the instructions provided with your gas hob state that the required distance between the hob and extractor must
be greater than 700mm, then that is the distance that should be observed; this is a legal requirement and may lead to
your hob being disconnected from the gas supply and the installation being reported to RIDDOR (The height should be
measured from the top of the burners).
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE
BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm.
The width of any hob must not be greater than the width of the extractor installed above it.
Mounting your Extractor
The extractor can be mounted in one of two ways:
1. Mark out the dimensions of the cut-out based on your
hood; the dimensions required are as follows: -
Version
CCA5
CCA7
Cut-out Width
Cut-out Depth
495
695
257
257
2. Hold the extractor in the housing and secure to the
canopy using 4 wood screws, located in the corner of
the extractor, as shown as C in figure 3. We
recommend that you seek the help of another individual
when carrying out this task.
3. Connect the exhaust pipe to the duct adapter (B in
figure 2.) and locate on the extractor, as indicated. We
recommend the use of 120mm (5”) ducting, although
100mm can be used with the use of a 120-100mm
converter; Note that this will affect performance.
ꢀ
Fig. 3
Figure 3 shows how the extractor should be vented: -
External Exhaustion
CANOPY
Internal Recirculation
CANOPY
Fig. 4
To contact our Customer Care Department, or for Service,
please contact us on the details below.
Customer Care Department • The
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY
|