CSI Model 10164-L Sampler
Control Cable for use with Isco
and Sigma Autosamplers
1/99
C o p y r i g h t ( c ) 1 9 9 8 - 1 9 9 9
C a m p b e l l S c i e n t i f i c , I n c .
CSI MODEL 10164-L SAMPLER CONTROL CABLE
FOR USE WITH ISCO AND SIGMA AUTOSAMPLERS
The 10164-L sampler control cable enables a datalogger to trigger an Isco, American Sigma, or
connector-compatible autosampler. Through this cable, the datalogger can inhibit the sampler from
running its programmed sampling routine and sense and record when the sampler indicates that it has
taken a sample. The following examples illustrate its use. Each of these functions are independent of
the others and you may combine functions as desired. You should insulate and tuck out of the way any
unused wires.
Trigger Sampler
Sense Sampler Event Markers
Wire color
CR10
21X
BDR320
Pulse port method:
purple
yellow
red
G
Ground
Control 2
+12
GND
C2
12V
GND
Wire color
CR10
21X
BDR320
C2
12V
G
purple
orange
clear
G
P1
G
Ground
Pulse 1
Ground
GND
P1
GND
clear
Ground
To trigger the sampler, pulse port 2 using a set
of instructions such as follows:
To sense sampler events, use Instruction 3 with
a configuration code of 0 (no configuration code
or Reps are required for the BDR320):
Do (P86)
1:
42
Set Port 2 High
Pulse (P3)
; Note: The 50 in the third parameter keeps the
; port high for 0.5 seconds. Some users have
; reported using a delay of 1 sec (100 in
; parameter 3) to ensure reliable triggering of
; the sampler.
1:
2:
3:
1
1
0
Reps
Pulse Input Chan
High frequency
(configuration code)
Loc [:EVENTS]
Mult
4:
5:
6:
2
1
0
Offset
Excitation with Delay (P22)
1:
2:
3:
1
0
50
Ex Channel
Delay W/Ex (units = 0.01 sec)
Delay After Ex (units = 0.01
sec)
To record the events in the datalogger's final
storage area, remember to totalize the events
temporarily stored in Input Location 2 in this
example.
4:
0
mV Excitation
Do (P86)
1:
CR10 control port interrupt method:
52
Set Port 2 Low
For the CR10, there is another useful method for
sensing and recording sampler events. This
method uses the control port 8/subroutine 98
interrupt feature of the CR10. Each time the
sampler reports an event, the CR10 records the
sample number with a time stamp in final storage.
In this example, sampler events will show up as
output arrays with an array ID of 400.
For the CR10 and the 21X, you can also supply
the trigger signal from switched excitation if no
control ports are available. In this case,
connect the yellow cable to the desired
excitation channel (say E3) and pulse the
channel using Instruction 22 as follows:
Excitation with Delay (P22)
1:
3
EX Chan (or the channel
you select)
Delay w/EX (units=0.01sec)
Delay after EX (units=0.01sec)
mV Excitation
Wire color
CR10
purple
orange
clear
G
C8
G
2:
3:
50
0
4: 2500
1
CSI MODEL 10164-L SAMPLER CONTROL CABLE
FOR USE WITH ISCO AND SIGMA AUTOSAMPLERS
CR10 Program (Subroutine 98 in Program Table 3)
Technical details of cable design:
*
3
Table 3 Subroutines
Wire color
brown
Via
Connector pin
1: Beginning of Subroutine (P85)
direct
direct
direct
D
1:
98
Subroutine Number
Z Loc [ Sample_No ]
green
F
2: Z=Z+1 (P32)
1: 10
purple
B
yellow
solid state
none (controls C)
3: Do (P86)
1: 10
relay circuit
Set high Flag 0 (output
flag)
red
solid state
relay circuit
C
4: Set Active Storage Area (P80)
orange
clear
20Kohm
resistor
E
1:
2:
1
400
Final Storage Area 1
Array ID or location
cable shield
no connection
5: Real Time (P77)
1: 1110
Year,Day,Hour-Minute
6: Sample (P70)
1:
2:
1
10
Reps
Loc [ Sample_No ]
7: End (P95) ;of Subroutine Number 98
End Table 3
Inhibit Sampler’s Program
Wire color
CR10 21X
BDR320
purple
G
Ground GND
(Isco) green
(Sigma) brown C1
clear
C1
Control 1
Control 1
Ground
C1
C1
GND
G
To inhibit an Isco sampler from running its own
program, set control port 1 low using a program
control instruction such as Instruction 86. To
allow the sampler to run its program, set it high.
NOTE: The logic for Sigma samplers is just
the opposite. A high signal inhibits the
sampler.
Example for inhibiting an Isco sampler's
program:
Do (P86)
1:
51
Set Port 1 low ;(41 would
set it high)
2
This is a blank page.
Campbell Scientific Companies
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321
UNITED STATES
Campbell Scientific Africa Pty. Ltd. (CSAf)
PO Box 2450
Somerset West 7129
SOUTH AFRICA
Campbell Scientific Australia Pty. Ltd. (CSA)
PO Box 444
Thuringowa Central
QLD 4812 AUSTRALIA
Campbell Scientific do Brazil Ltda. (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
CANADA
Campbell Scientific Ltd. (CSL)
Campbell Park
80 Hathern Road
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
Campbell Scientific Ltd. (France)
Miniparc du Verger - Bat. H
1, rue de Terre Neuve - Les Ulis
91967 COURTABOEUF CEDEX
FRANCE
Campbell Scientific Spain, S. L.
Psg. Font 14, local 8
08013 Barcelona
SPAIN
|