MA1002-EA
Operation Guide ANALOG (MAB)
• Your watch may differ somewhat from the one shown in the illustration1
Notes
•
Some water resistant models are equipped with a screw lock
crown1
With such models, you must unscrew the crown in the direction
noted in the illustration to loosen it before you can pull it out1
Do not pull too forcibly on such crowns1
Also note that such watches are not water resistant while their
crowns are loosened1 Be sure to screw the crowns back in as
far as they will go after making any setting1
•
•
[
Module 5128]
To set the time
First click (Day setting)
Crown
11 When the second hand is at 12 o’clock, pull out the
crown to the second click to stop it1
(Normal position)
21 Set the hands by rotating the crown1 Move the
minute hand four or five minutes past the setting
you want, and then back them up to the setting1
31 Push the crown back in on a time signal to resume
timekeeping1
To set the day
• Avoid setting the day between 9:00 p1m1 and 1:00
a1m1 The day may not change in the following day if
you do1
Second click
(Time setting)
11 Pull out the crown to the first click1
21 Set the day by rotating the crown1
31 Push the crown back in to its normal position1
[Modules 5125 and 5167]
To set the time
First click
(Day, day of week setting)
11 When the second hand is at 12 o’clock, pull out the
crown to the second click to stop it1
Crown
(Normal position)
21 Set the hands by rotating the crown1 Move the
minute hand four or five minutes past the setting
you want, and then back them up to the setting1
31 Push the crown back in on a time signal to resume
timekeeping1
To set the day and day of the week
• Avoid setting the day and day of the week between
9:00 p1m1 and 5:00 a1m1 The day and day of the
week may not change in the following day if you do1
11 Pull out the crown to the first click1
Second click
(Time setting)
21 Set the day by rotating the crown counterclockwise1
31 Set the day of the week by rotating the crown clockwise1
41 Push the crown back in to its normal position1
•
For watch with the elapsed time bezel
Rotate the elapsed time bezel to align the
minute hand1
mark with the
After certain amount of time elapsed, read the graduation on the
elapsed time bezel which the minute hand points to1
The elapsed time is indicated1
Elapsed time bezel
Specifications
Accuracy at normal
temperature
(per month)
Module No1
Battery type
Battery life
5125/5128
5167
20 seconds
20 seconds
SR626SW
SR920SW
Approx1 3 years
Approx1 5 years
1
|