Model 935CB
OWNER’S MANUAL
Motion Detecting Control Panel
WARNING
FOR USE WITH GARAGE DOOR OPENERS
MANUFACTURED AFTER JANUARY 1, 1995.
This door control contains a motion detector
that will automatically turn on the light when it
detects a person entering the garage. This
feature can be easily turned off for extended
work light use.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
®
• Be sure power is not connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
Locate the door control within sight of the door at
a minimum height of 5 feet (1.5 m) where small children
cannot reach, and away from moving parts of the door and
door hardware.
• Install door control within sight of garage door, out of reach of
children at a minimum height of 5 feet (1.5 m), and away from
all moving parts of door.
• NEVER permit children to operate or play with door control push
buttons or remote control transmitters.
NOTE: After installation, an indicator light behind the cover
will indicate proper connection. If not lit, the Lock and Light
features will not function (reverse wires to correct).
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
INSTALLATION
The door control is typically attached directly to the wall. For
pre-wired installations (as in new home construction), it can
be mounted to a standard single gang box. See illustrations.
If installing the door control adjacent to existing door
controls, be sure the detector switch is accessible.
NOTE: The push bar may stick if the door control is not
mounted on a smooth surface. If a click is not heard when
pressing the push bar, loosen the two mounting screws or
relocate the door control to a smoother surface.
4. (Standard installation only) Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to
secure wire in several places. Do not pierce wire with a
staple, creating a short or open circuit.
1. Disconnect power to the garage door opener.
2. Strip 7/16" (11 mm) of insulation from one end of bell wire
and connect to the two screw terminals on back of door
control by color: white wire to 2 and white/red wire to the 1.
5. Strip 7/16" (11 mm) of insulation from end of bell wire. For
quick-connect terminals, connect bell wire as follows:
white to white and white/red to red. For opener terminal
screws, connect white to 2 and white/red to 1.
3. Remove white cover by gently prying at slot in top of the
cover with a small flat head screwdriver. Fasten with
6ABx1-1/4" self-tapping screws (drywall installation) or
6-32x1" machine screws (into gang box) as follows:
• Drill and install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
OPENER TERMINAL SCREWS
• Position bottom of door control on screw head and slide
down to secure. Adjust screw for snug fit.
Push Bar
1
2
3
• Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
7/16"
(11 mm)
• Insert top tabs and snap on cover.
Strip wire 7/16" (11 mm)
STANDARD WALL MOUNT
STANDARD WALL MOUNT
STANDARD WALL OUNT
LOCK
LIGHT
To Replace
Insert Top
Tabs First
Lock
Button
Opener Panel
Antenna
Light Button
QUICK-CONNECT TERMINALS
To release wire,
push in tab with
screwdriver tip
Detector
Switch
Top Mounting Hole
L
O
C
K
L
IG
H
T
24 Volt
Bell Wire
ON
OFF
Push Bar Cover
2
W
ITE
H
Door
Control
Terminal
Screws
PRE-WIRED INSTALLATION
STANDARD WALL MOUNT
PRE-WIRED INSTALLATION
1
D
E
R
24 Volt
2-Conductor
Bell Wire
Red
Grey
White
Bottom
Mounting
Back View Hole
To Replace
Insert Top
Tabs First
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red, or
for terminal screws: attach white to 2 and white/red to 1.
L
O
C
K
Detector
Switch
ON
OFF
L
IG
H
T
The automatic light feature will become functional 1-1/2
minutes after power is restored.
Push Bar Cover
|