Owner's Instructions:  
The Garage Door Opener Surge Protector is designed to protect garage door  
openers against damage from lightning and power surges. The Surge Protector  
will stop radiated surge currents from coming through wall control and saftey  
sensor wires, as well as surge currents from coming through AC power line  
according to the rating chart shown below.  
Plug the Surge Protector into grounded (3-wire) 120V AC outlet within four (4)  
feet of the garage door opener. Plugging Surge Protector into a GFCI (Ground  
Fault Circuit Interrupter) is acceptable, but not recommended as power surges  
may cause the GFCI to trip and you will need to reset the outlet in order to oper-  
ate the garage door opener.  
3
Door  
Bell  
Wall  
Control  
or  
3
2
2
LOCK LIGHT  
WARNING  
Garage Door  
To prevent possible SERIOUS INJURY or DEATH from electrocution:  
• Unplug Garage Door Opener from AC outlet and be sure power is disconnected BEFORE installing the Surge Protector.  
• Connect terminals ONLY to 24 VOLT low voltage wires.  
To wall control  
input connectors  
Garage Door Opener  
• The Surge Protector is ONLY for indoor Use.  
• DO NOT perform installation during a lightning storm (visible lightning)  
9
1
9
1
7
3
7
3
5
5
KG  
KG  
To protect the door opener low voltage control wires from lightning damage, control wires will be rerouted from the door opener to the surge protector, continuing the  
connection to the door opener. This protects the opener’s control wiring.  
SAFETY SENSORS  
To IR sensor  
input connectors  
Before you begin:  
protector, use the 5’ piece of white-white/black 24  
AWG bell wire (included) as EXTENSION from  
surge protector to opener.  
• Note polarity/wire colors, twist original wire with  
extension wire together, and insert into surge  
protector. The terminals colored white and gray on  
the surge protector are designated for the IR  
sensor wires.  
Follow these steps:  
It is recommended that you label wires prior to  
removing them from the garage door opener. Label  
safety sensor wires and wall control wires using  
color codes if applicable.  
1. Unplug Surge Protector and garage door opener  
from AC outlet.  
2.Verify that the safety sensor wires are connected  
to the gray and white terminals on the Surge  
Protector. If not, re-wire Surge Protector  
following above instructions.  
3. If connected to the gray and white terminals and  
LED's are still not illuminated, disconnect the  
twisted wires from both gray and white terminals  
and switch positions. Ensure they are making a  
good connection within the terminals of the Surge  
Protector.  
FOR TECHNICAL SUPPORT, DIAL OUR TOLL FREE NUMBER: (USA) 1-800-528-9131, www.chamberlain.com  
Chamberlain Connected Equipment Limited Warranty  
Installing the wall control wires:  
• At the garage door opener, remove the wall control  
wires from opener terminals, noting polarity and/or  
wire color positions.  
• Since these wires will now be routed to the surge  
protector, use the 5’ piece of white-white/red 24  
AWG bell wire (included) as EXTENSION from  
surge protector to opener.  
• Note polarity/wire colors, twist original wire with  
extension wire together, and insert into surge  
protector. The terminals colored red and white on  
the surge protector are designated for the doorbell  
button/wall control wires.  
• Attach wires to opener terminals in same order/  
color combination as original installation. (Consult  
owners manual if necessary).  
Chamberlain warrants to the original purchaser of any  
If you wish to make a warranty claim, please call 800-  
528-9131 for instructions. You will need your receipt for  
the Chamberlain Surge Protector. All above warranties  
are null and void if the Chamberlain Surge Protector in  
use during the occurrence is not provided to  
Chamberlain for inspection upon Chamberlain’s request  
at the sole expense of the purchaser, Chamberlain  
determines that the Chamberlain Surge Protector has  
been improperly installed, altered in any way or tam-  
pered with, Chamberlain determines that the damage  
did not result from the occurrence or that no occurrence  
in fact took place, or Chamberlain determines that the  
Connected Equipment was not used under normal oper-  
ating conditions or in accordance with all labels and  
instructions.  
THIS LIMITED WARRANTY IS IN LIEU OF ANY  
• Attach wires to opener terminals in same order/  
color combination as original installation. (Consult  
owners manual if necessary).  
Chamberlain Surge Protector that the surge protector  
shall be free of defects in material and workmanship for  
a period of one (1) year from the date of original pur-  
chase, and will repair or replace, at its option, any  
defective surge protector free of charge. The proper  
operation of the Chamberlain Surge Protector may  
destroy the protector itself. Such an event is not a defect  
and is not covered by this limited warranty.  
OTHER WARRANTIES, EXPRESS OR IMPLIED,  
INCLUDING ANY IMPLIED WARRANTY OF MER-  
CHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE, OR OTHERWISE, AND OF ANY OTHER  
OBLIGATIONS OR LIABILITY ON SELLER’S PART.  
THIS LIMITED WARRANTY DOES NOT COVER NON-  
DEFECT DAMAGE, DAMAGE CAUSED BY IMPROP-  
ER INSTALLATION, OPERATION OR CARE  
(INCLUDING, BUT NOT LIMITED TO ABUSE, MIS-  
USE, FAILURE TO PROVIDE REASONABLE AND  
NECESSARY MAINTENANCE, UNAUTHORIZED  
REPAIRS OR ANY ALTERATIONS TO THIS PROD-  
UCT), REPLACEMENT OF BATTERIES AND LIGHT  
BULBS OR UNITS INSTALLED FOR NON-RESIDEN-  
TIAL USE.  
Installing the Surge Protector:  
• Plug Surge Protector into AC outlet  
• Plug garage door opener into outlet on front of  
Surge Protector  
•Test garage door opener for proper operation. Be  
sure to test all functions including wall control,  
keypad, safety sensors (Door Reversal Test - See  
garage door opener manual for instructions) and  
any other accessories.  
4. Reconnect AC power to both Surge Protector and  
garage door opener.  
For a period of one (1) year from the date of original pur-  
chase of any Chamberlain Surge Protector,  
Chamberlain will provide up to $100 to repair or replace,  
at its option, damaged garage door opener parts or  
components (“Connected Equipment”) which is dam-  
aged by a transient voltage surge (an “Occurrence”),  
while properly connected through a Chamberlain Surge  
Protector to a properly wired AC power line with protec-  
tive ground. This limited warranty is null and void unless  
all wires leading into the equipment pass through an  
appropriate Chamberlain Surge Protector as further  
described herein. Chamberlain reserves the right to  
review the damaged Chamberlain Surge Protector, the  
damaged Connected Equipment and the site where the  
damaged occurred. All costs of shipping the  
Chamberlain Surge Protector and the damaged equip-  
ment to Chamberlain for inspection shall be borne sole-  
ly by the purchaser. Damaged equipment must remain  
available for inspection until the claim is finalized. The  
Chamberlain Surge Protector is not intended for use  
with any product(s) other than Connected Equipment.  
LED Indicator: The indicator light should be illumi-  
nated when the surge protector is plugged into AC  
power and is protecting your garage door opener  
system. If the indicator light goes out, the surge  
protector has sacrificed (depleted) itself to protect  
the garage door opener system and should be  
replaced immediately.  
All Chamberlain Surge Protectors must be plugged  
directly into the power source and must not be “daisy-  
chained” together in serial fashion with other power  
strips, UPS, other surge protectors or extension cords.  
Any such installation voids the limited warranty. This  
limited warranty only protects against damage to prop-  
erly connected equipment where Chamberlain has  
determined, in its sole discretion, that the damage  
resulted from an Occurrence, and does not protect  
against acts of God such as flood, earthquake, direct  
lightning strike, war, vandalism, theft, normal-use wear  
and tear, erosion, depletion, obsolescence, abuse,  
damage due to low voltage disturbances (i. e.  
brownouts or sags), non-authorized program or system  
equipment modification or alteration. This warranty is  
secondary to any existing coverage of any Connected  
Equipment, including, but not limited to, any manufac-  
turer’s warranty, extended warranties or insurance cov-  
erage.  
Note: After completing installation and restoring  
power to the garage door opener, check illumination  
of safety sensor LED's (located on safety sensors).  
If not illuminated, the wires for the safety sensors  
may be crossed at the Surge Protector.  
UNDER NO CIRCUMSTANCES SHALL SELLER BE  
LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR  
SPECIAL DAMAGES ARISING IN CONNECTION  
WITH USE, OR INABILITY TO USE, THIS PRODUCT.  
IN NO EVENT SHALL SELLER’S LIABILITY FOR  
BREACH OF WARRANTY, BREACH OF CONTRACT,  
NEGLIGENCE OR STRICT LIABILITY EXCEED THE  
COST OF THE PRODUCT COVERED HEREBY. NO  
PERSON IS AUTHORIZEDTO ASSUME FOR US ANY  
OTHER LIABILITY IN CONNECTION WITHTHE SALE  
OF THIS PRODUCT.  
Installing the safety sensor wires:  
• At the garage door opener, remove the safety  
sensor wires from opener terminals, noting  
polarity and/or wire color positions.  
•Since these wires will now be routed to the surge  
RATING CHART / TECHNICAL SPECIFICATIONS  
Power:__________________________1800 Watts  
UL1449 Suppression Rating:______________800V  
Protection Modes:________________L-N, N-G, L-G  
Energy Dissipation:__________________761 joules  
Protection Indicator Light:__________________Yes  
Catastrophic Surge Circuit:_________________Yes  
Thermal Fusing: _________________________Yes  
Line Voltage:________________120 VAC, 50/60Hz  
Maximum Surge Current:_________________16kA  
Maximum Surge Voltage:__________________6kV  
Line Current:____________________________15A  
Valid only in the USA and Canada.  
NOTE: The Chamberlain Garage Door Opener Surge Protector is not recommended to be installed with garage door openers manufactured by Marantec America  
Corporation or Hoermann, Inc. USA.  
114A2915 Rev A  
Printed in China  
© 2004, All Rights Reserved The Chamberlain Group, Inc.  
 

Black Box Network Card KV1308C User Manual
Black Decker Cordless Drill 5146471 01 User Manual
Black Decker Edger FHV1200W User Manual
Black Decker Sander 90532198 User Manual
Bostitch Nail Gun 175616REVB User Manual
Breville Coffeemaker BDC600XL User Manual
Broan Bathroom Aids 820 User Manual
Campbell Hausfeld Vacuum Cleaner IN465300AV User Manual
Chief Manufacturing Indoor Furnishings LCD2TS User Manual
Cisco Systems Computer Hardware 1240AG User Manual