Chauvet Indoor Furnishings TFX 125BL User Manual

TFX-125BL  
Shadow™ 125  
USER MANUAL  
Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A  
(800) 762-1084 – (954) 929-1115  
FAX (954) 929-5560  
 
BEFORE YOU BEGIN  
What is included  
¾
¾
¾
¾
TFX-125BL fixture  
H-125BL Blacklight bulb  
Power cord with plug  
Warranty Card & Manual  
Unpacking Instructions  
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that  
all parts are present, and have been received in good condition. Notify the shipper immediately and  
retain packing material for inspection if any parts appear damaged from shipping or the carton itself  
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture  
must be returned to the factory, it is important that the fixture be returned in the original factory box  
and packing.  
AC Power  
To determine the power requirements for a particular fixture, see the label affixed to the back plate of  
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average  
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and  
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the  
rheostat or dimmer channel is used solely for a 0% to 100% switch. Before  
applying power to a fixture, check that the source voltage matches the  
fixture’s requirement. Check the fixture or device carefully to make sure that  
if a voltage selection switch exists that it is set to the correct line voltage you  
will use.  
Figure 1 - AC Voltage Switch  
Warning!  
Verify that the power select switch on your unit matches the  
line voltage applied. All fixtures must be connected to circuits  
with a suitable Earth Ground.  
Not all fixtures have a voltage  
select switch. Please be sure to  
connect to the proper voltage.  
Safety Instructions  
Please read these instructions carefully, which includes important  
information about the installation, usage and maintenance?  
Please keep this User Guide for future consultation. If you  
sell the unit to another user, be sure that they also receive  
this instruction booklet.  
Always make sure that you are connecting to the proper  
voltage and that the line voltage you are connecting to is  
not higher than that stated on decal or rear panel of the  
fixture.  
This product is intended for indoor use only!  
To prevent risk of fire or shock, do not expose fixture to  
rain or moisture. Make sure there are no flammable  
materials close to the unit while operating.  
The unit must be installed in a location with adequate  
ventilation, at least 50cm from adjacent surfaces. Be sure  
that no ventilation slots are blocked.  
Always disconnect from power source before servicing or  
replacing lamp or fuse and be sure to replace with same  
lamp source.  
Secure fixture to fastening device using a safety chain.  
Never carry the fixture solely by its head. Use its carrying  
handles.  
Maximum ambient temperature is Ta: 40°. Do not operate  
fixture at temperatures higher than this.  
In the event of serious operating problem, stop using the  
unit immediately. Never try to repair the unit by yourself.  
Repairs carried out by unskilled people can lead to  
damage or malfunction. Please contact the nearest  
authorized technical assistance center. Always use the  
same type spare parts.  
Don’t connect the device to a dimmer pack.  
Make sure power cord is never crimped or damaged.  
Never disconnect power cord by pulling or tugging on the  
cord.  
Avoid direct eye exposure to lamp while it is on.  
Caution!  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET.  
TFX-125BL User Manual  
3
Revision: 2004-11-02/11:32  
 
         
INTRODUCTION  
Features  
high-powered 125-watt blacklight cannon  
long throw  
easy lamp access  
safety wire mesh  
switch-selectable power settings 115V or 230V, (240V available)  
no duty cycle!  
Product Overview  
Hanging bracket  
Tension knob  
Lamp wire mesh cover  
Product Overview  
TFX-125BL User Manual  
4
Revision: 2004-11-02/11:32  
 
     
SETUP  
Lamp  
You will need to install a lamp prior to the initial operation of the fixture. A bulb is included with your  
product.  
Warning!  
When replacing the lamp, please wait 15 minutes after powering down to allow the  
unit to cool down! Always disconnect from main power prior to lamp replacement.  
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp  
with alcohol and wipe it with a lint free cloth before installation.  
LAMP INSTALLATION  
Figure 2 – TFX-125 Lamp Installation  
1) Remove both thumbscrews located on the front of the  
fixture and open the lamp cover.  
2) If replacing the lamp, remove old lamp first by unscrewing it  
from its base.  
3) Hold the new lamp with a lint-free cloth or napkin and screw  
lamp into the socket providing minimal torque to secure  
lamp in place.  
4) Close lamp cover, align the screw holes and fasten the  
thumbscrews back onto the cover.  
Remove both thumbscrews  
Power  
Your product is equipped with switch-selectable AC power  
setting and frequency.  
Slide switch up or down depending  
on your line voltage.  
Warning!  
Verify that the power select switch on your unit  
matches the line voltage applied. All fixtures must  
be connected to circuits with a suitable Earth  
Ground.  
To determine the power requirements for a particular fixture, see the label affixed to the back plate  
of the fixture or refer to the fixture’s specifications chart.  
A fixture’s listed current rating is its average current draw under normal conditions.  
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat  
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%  
to 100% switch.  
Before applying power to a fixture, check that the source voltage matches the fixture’s  
requirement.  
All fixtures must be connected to circuits with a suitable Earth Ground.  
When in doubt, please consult a qualified electrician to determine the frequency in your locale.  
TFX-125BL User Manual  
5
Revision: 2004-11-02/11:32  
 
       
Setup  
Mounting  
ORIENTATION  
This fixture may be mounted in any position provided there is adequate room for ventilation.  
RIGGING  
Figure 3 - Clamp  
Mount the fixture using, a suitable “C” or “O” type clamp. Adjust the  
angle of the fixture by loosening both knobs and tilting the fixture.  
After finding the desired position, retighten both knobs.  
When selecting installation location, take into consideration lamp  
replacement access and routine maintenance.  
Safety cables should always be used.  
Never mount in places where the fixture will be exposed to rain,  
high humidity, extreme temperature changes or restricted  
ventilation.  
Note!  
Clamp is sold separately.  
Operation  
The Shadow 125, also known as the TFX-125BL, produces a high powered long throw, medium sized  
beam of black light. Black light causes fluorescent materials to emit visible light. This effect is  
commonly used in nightclub entrances and dance floors.  
The TFX-125BL is a stand alone fixture. AC voltage is all that is required to operate. This unit is best  
used at a throw distance of between 18 and 26 feet due to a parabolic reflector system that focuses  
and harnesses the light into a medium sized beam.  
Weighing in at 17 lbs and consuming only 125 watts of power, the TFX-125BL does lend itself for  
mobile applications. However, always tilt the fixture to project below eye level as the intensity of the  
beam could have an irritating effect to patrons who stare at its luminosity. We recommend a lighting  
stand that is capable of extending a minimum of 9 feet and a position farthest away from the dance  
floor.  
TFX-125BL User Manual  
6
Revision: 2004-11-02/11:32  
 
       
APPENDIX  
General Maintenance  
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage  
and environment are contributing factors in determining frequency. As a general rule, fixtures should  
be cleaned at least twice a month. Dust build up reduces light output performance and can cause  
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off  
fixture before conducting maintenance.  
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust  
collected on external vents and internal components. Clean all glass when the fixture is cold with a  
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply  
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical  
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil  
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or  
becomes dirty, clean the lamps with an alcohol wipe.  
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to  
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:  
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s  
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean  
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.  
Returns Procedure  
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.  
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products  
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the  
fixture. Be prepared to provide the model number, serial number and a brief description of the cause  
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate  
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to  
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe  
method to use.  
Claims  
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be  
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and  
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim  
for items such as missing component/part, damage not related to shipping, and concealed damage,  
must be made within seven (7) days of receiving merchandise.  
TFX-125BL User Manual  
7
Revision: 2004-11-02/11:32  
 
       
Appendix  
General Troubleshooting  
Applies to  
Dimmer  
Foggers  
Lights & Snow  
Controller  
s
s&  
Chaser  
Symptom  
Solution(s)  
9
Auto shut off  
Check fan thermal switch reset  
Beam is very dim or not Clean optical system or replace lamp  
9
bright  
Check 220/110v switch for proper setting  
Breaker/Fuse keeps  
blowing  
Check total load placed on device  
9
9
9
9
9
9
9
Chase is too slow  
Check users manual for speed adjustment  
Device has no power  
Check for power on Mains.  
Check device’s fuse. (internal and/or external)  
Fixture is not responding Check DMX Dip switch settings for correct addressing  
Check DMX cables  
9
9
Check polarity switch settings  
Fixture is on but there is Make sure you have the correct audio mode on the control  
no movement to the  
audio  
switches. If audio provided via ¼” jack, make sure a live audio  
signal exists  
9
9
Adjust sound sensitivity knob  
Lamps cuts off  
sporadically  
Possible bad lamp or fixture is overheating.  
Lamp may be at end of its life.  
9
9
Light will not come on  
after power failure  
Some discharge lamps require a cooling off period before the  
electronics in the fixture can kick start it again, wait 5 to 10  
minutes before powering up  
Loss of signal  
Use only DMX cables  
Install terminator  
Note: Keep DMX cables separated from power cables or black  
lights.  
9
9
9
9
9
9
Motor movements are  
jerky or jumpy  
Possible bad motor driver or sensors  
Check polarity switch on controller  
9
9
Moves slow  
Check 220/110v switch for proper setting  
No flash  
Re-install bulb, may have shifted in shipping  
No light output  
Check slip ring & brushes for contact  
Install bulb  
9
Call service technician  
Relay will not work  
Check reset switch  
9
Check cable connections  
9
9
9
Remote does not work  
Stand alone mode  
Make sure connector is firmly connected to device  
All Chauvet lighting fixtures featuring stand-alone functions do  
not require additional settings, simply power the fixture and it  
will automatically enter into this mode  
Unit wobbles when  
rotating  
Check for damages possibly incurred during shipping  
9
TFX-125BL User Manual  
8
Revision: 2004-11-02/11:32  
 
 
Appendix  
Technical Specifications  
WEIGHT & DIMENSIONS  
Length............................................................................................................................. 216 mm (8.5 in)  
Width ............................................................................................................................... 254 mm (10 in)  
Height .............................................................................................................................. 254 mm (10 in)  
Weight .............................................................................................................................. 7.7 Kg (17 lbs)  
POWER  
Switch-selectable power settings ..................................................................115V 60 Hz or 230V 50 Hz  
European version ..................................................................................................................240V 50 Hz  
AC input........................................................................................3 prongs IEC 60320 C14 male socket  
LAMPS  
CHAUVET H-125BL....................................................................................................................... 125W  
THERMAL  
Maximum ambient temperature............................................................................................ 40° (104° F)  
FUSE  
Main............................................................................................................... 20mm Glass 5A Fast Blow  
ORDERING INFORMATION  
Shadow-125 .......................................................................................................................... TFX-125BL  
Fuse 5A ............................................................................................................................P170FUSE005  
TFX-125BL User Manual  
9
Revision: 2004-11-02/11:32  
 
 

Bissell Vacuum Cleaner 81L2 User Manual
Bolens Trimmer 24604 9 User Manual
Bosch Appliances Home Security System FW550 User Manual
Bose Stereo Amplifier 3 Series User Manual
Boss Audio Systems Car Stereo System BV9564BI User Manual
Boston Acoustics Stereo System MicroSystem CD User Manual
Breville Fryer BDF450XL User Manual
Butler Coffeemaker 645 067 User Manual
Carrier Air Conditioner 09BB User Manual
Carrier Refrigerator HS070 160 User Manual