Foot Master™ 4200
FS-4200
USER MANUAL
CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
2007-02-13/14:05
1. Before You Begin
Unpacking Instructions
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
Note:
If you should require sending any items back to CHAUVET, call CHAUVET for a (RA)
Return Authorization number. The factory will not allow any shipments without an RA.
Your shipment includes the following:
1 x Foot Master Switch
1 x Foot Master Relay Pack
1 x Power cable
1 x Serial link cable
Warranty Card
Users Manual
Contact Us
World Wide
General Information
Chauvet Lighting
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115
fax:
954.929.5560
toll free: 800.762.1084
Technical Support
Chauvet Lighting
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115 (Press 4)
fax:
954.929.5560 (Attention: Service)
World Wide Web
FS-4200 User Manual
3
2007-02-13/14:05
Before You Begin
Safety Instructions
Please read these instructions carefully, which
includes important information about the installation,
usage and maintenance of this product.
•
•
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
•
•
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
•
•
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing lamp or fuse and be sure to
replace with same lamp source.
•
•
Secure unit to fastening device using a safety chain.
Maximum ambient temperature (Ta) is 95°F (35°C). Do not operate unit at temperatures higher than
this.
•
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
•
•
•
•
•
Don’t connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source while it is on.
Do not daisy chain power to more than 4 units.
Caution!
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET at: 954-929-1115.
FS-4200 User Manual
4
2007-02-13/14:05
2. Introduction
Features
•
•
•
•
Pre-programmed foot controller
Foot controller powered through included relay pack
4 channels with on/off switches
Four chase options:
a) 16 pattern sound activation with sensitivity adjustment
b) Adjustable timed chase
c) Full on override
d) Blackout override
•
•
•
•
Manual override available for all control options
Includes 1 relay pack with 8 sockets (2 sockets per channel) and SF-EXCB linking cable
Additional linkable relay packs available (max 4 units, model: SR-8)
Additional power output for daisy chaining packs together
FS-4200 User Manual
5
2007-02-13/14:05
Introduction
Product Overview
SOUND CHASE
AUTO CHASE
Activates the
sound active
chase
Activates the
auto run chase
BLACKOUT
FULL ON
Will shut all
lights off
Turn on all
outputs on the
relay pack.
PEDAL SWITCH
Each pedal will turn
on or off power to
devices connected
SPEED
CONTROL
LINK OUT
SOUND
SENSITIVITY
CONTROL
Built-in Mic.
HANGING
BRACKET
POWER
OUTLET
2 outlets per
channel
Power
Indicator
LINK OUT
Provides connection to
an optional second
SR8 relay pack
POWER
OUTLET
Always On
LINK IN
AC VOLTAGE
SWITCH
Connects to
Foot Switch
RESETTABLE
CIRCUIT
120V/230V
BREAKER
POWER INPUT
FS-4200 User Manual
6
2007-02-13/14:05
3. Setup
AC Power
Warning!
Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
•
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
•
•
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
•
•
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Power Cable Configuration
CABLE
BROWN
Pin
Live
International
Screw Color
Yellow or Brass
Silver
L
N
BLUE
Neutral
Earth
YELLOW/GREEN
EG (Ground)
Green
Mounting
Orientation
This power relay-pack can be mounted on a truss using a clamp in any position or against a flat
surface using the screw holes
Rigging
Hanging Clamp
The relay pack includes (3) clamp mounting holes for convenience
of placement. You only need to use one to adhere to a truss or light
stand. You must supply your own clamp and make sure the clamp is
capable of supporting the weight of the relay pack. You can order C-
clamps from any CHAUVET dealer or distributor.
1.
Block access below the work area and use
suitable and stable platform when installing or
servicing the relay pack.
2.
3.
4.
Affix clamp to relay-pack using any of the (3)
clamp holes provided.
Surface
mounting
Verify the structure can hold 10 times the weight
of all to-be installed fixtures.
Always use a safety cable or chain as a
secondary source of attachment. The safety
cable must hold 10 times the weight of the
accessory. If safety cable attachment point is
provided that is permanently affixed to the
surface or body of the fixture, use that instead of
looping through a hanging yoke/arm.
FS-4200 User Manual
7
2007-02-13/14:05
4. Operating Instructions
Using the FS-4200
The Foot Master™ 4200 comes with a relay pack and foot controller. The relay pack has 16 built in
chase patterns that can be triggered either by sound or automatically using the foot controller. The
foot controller provides additional control options such as;
•
•
•
•
•
Full On : Will turn on all power on all receptacles
Sound : All chase patterns will be triggered via sound, the sensitivity to sound can be adjusted
Auto : Chase patterns will be triggered at a pre-determined speed
Blackout : All lights will be turned off momentarily or for as long as you hold the foot button
Individual ON/OFF pedals : Each output can be turned on or off independently.
Connection Diagram
LIGHTING
FIXTURE
LIGHTING
FIXTURE
LIGHTING
FIXTURE
LIGHTING
FIXTURE
Provides continuous power to any
device
CAUTION!
Relay Pack
Please limit your power use on this
output. The relay pack will only allow
15Amps of power.
Optional
additional SR8
relay pack
Serial Link Cable
Mains Power
Foot Master
FS-4200 User Manual
8
2007-02-13/14:05
5. Appendix
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
Maintenance
To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or
becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
FS-4200 User Manual
9
2007-02-13/14:05
Appendix
Technical Specifications
WEIGHT & DIMENSIONS
...............................................................................................................................................Relay Pack
Length........................................................................................................................... 8.25 in (210 mm)
Width ............................................................................................................................ 7.65 in (194 mm)
Height ............................................................................................................................. 2.75 in (70 mm)
Weight .................................................................................................................................5 lbs (2.2 kg)
............................................................................................................................................. Foot Switch
Length........................................................................................................................ 12.0 in (304.8 mm)
Width ........................................................................................................................... 6.5 in (165.1 mm)
Height ............................................................................................................................ 3.0 in (76.2 mm)
Weight ..........................................................................................................................3.56 lbs (1.59 kg)
POWER
Operating Voltage .........................................................................................110V 60 Hz or 230V 50 Hz
AC input........................................................................................................................... IEC 60320 C14
Load (110V)...........................................................(10A, 1100W) per channel, (15A, 1650W) maximum
Load (220V)...........................................................(10A, 2200W) per channel, (15A, 3300W) maximum
FUSE
Main................................................................................................................Resettable Circuit Breaker
ORDERING INFORMATION
Foot Master™ 4200....................................................................................................................FS-4200
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): [email protected]
Telephone: (954) 929-1115 - (Press 4)
Fax: (954) 929-5560 - (Attention: Service)
Website: http://www.chauvetlighting.com
FS-4200 User Manual
10
2007-02-13/14:05
|