Chief Manufacturing TV Mount MSP DCCMD User Manual

I N S T A L L A T I O N I N S T R U C T I O N S  
Medium Flat Panel  
Dual Swing Arm Wall Mount (JWD)  
Model MSP-DCCMD  
The JWD single swing arm wall mount was designed for  
mounting a medium sized flat panel display. The JWD  
can swing out from the wall or fold against the wall,  
depending on your ergonomic need. The mount itself can  
be tilted +15º. The amount of tilt left and right depends on  
the size and location of the display.  
The JWD is shipped with the VESA® 100mm/100mm  
Centris™ interface which is compatible with most medium  
flat panels. To accommodate the mounting hole patterns  
on existing medium flat panels that are offered in different  
sizes, the JWD is supplied with two interface adapters,  
listed below:  
The 200mm/100mm interface adapter  
The interface adapter that accomodates the  
400mm/200mm and 550mm/235mm hole  
patterns  
The JWD will more than likely adapt to your medium flat  
panel display, providing that your display does not exceed  
the specified weight rating.  
BEFORE YOU BEGIN  
CAUTION: To prevent damage to the JWD, which could affect or void the Factory warranty, and to the equipment  
that will be attached to it, thoroughly study all instructions and illustrations before you begin the installation. Pay  
particular attention to the “Important Warnings and Cautions” on Page 2.  
The maximum weight to be installed on the JWD wall mount is 75 pounds (34 kg).  
The JWD wall mount is designed to be installed using wall studs or supporting framework. The structure to which  
the JWD wall mount is anchored must be capable of supporting five times the total weight of the mount and all  
attached equipment.  
If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480.  
If a defect is discovered after Dell’s initial 21-day Customer Satisfaction period, Chief Mfg. will, at its option,  
repair or replace the product at no charge provided it is returned during the warranty period. Please note contact  
information for Chief Mfg. listed below:  
8832-000088 Rev. C  
©2006 Chief Manufacturing  
CHIEF MANUFACTURING INC.  
1-800-582-6480 952-894-6280 FAX 952-894-6918  
8401 EAGLE CREEK PARKWAY, STE 700  
SAVAGE, MINNESOTA 55378 USA  
Printed in USA 03/06  
 
Installation Instructions  
Model MSP-DCCMD  
CONTENTS  
Inspect The Unit Before Installing  
IMPORTANT WARNINGS AND CAUTIONS! .......... 2  
DIMENSIONS .......................................................... 2  
TOOLS REQUIRED FOR INSTALLATION ............. 3  
Inspect The Unit Before Installing ............................ 3  
SPECIFICATIONS ................................................... 3  
INTRODUCTION ..................................................... 3  
PARTS (Continued) ................................................. 5  
WALL BRACKET INSTALLATION .......................... 6  
Secure Wall Bracket ......................................6  
Attach Mount to Wall Bracket .........................6  
INSTALLATION (100mm x 100mm) ..............7  
Flush Mount Centris Bracket to Display ............7  
Recess Mount Centris Bracket to Display ........7  
INSTALLATION (200mm x 100MM)......................... 8  
Attach Interface Adapter to Display ...............8  
Attach Display to Centris Bracket ..................8  
INSTALLATION  
(400mm x 200MM and 550mm x 235MM) ............... 9  
Attach 400mm x 200mm Interface Adapter ...9  
Attach 550mm x 235mm Interface Adapter ...9  
Attach Display to Centris Bracket ..................9  
CABLE MANAGEMENT .......................................... 10  
ADJUSTMENTS ...................................................... 10  
LATERAL TENSION ADJUSTMENT .............10  
PITCH ADJUSTMENT ...................................10  
WARNING: Watch for pinch points. Do not put your  
fingers between movable parts.  
1. Carefully inspect the mount for shipping damage. If  
any damage is apparent, call your carrier claims  
agent and do not continue with the installation until  
the carrier has reviewed the damage.  
NOTE: Read all instructions before starting installation.  
2. Lay out components to ensure you have all the  
required parts before proceeding  
(see JWD drawing on page 4).  
SPECIFICATIONS  
Table 1 below provides the JWD specifications.  
Table 1: JWD Speifications  
Depth from  
Wall  
2-11/16” (68mm)  
Maximum  
Extension  
20-3/8” (51.8cm)  
Dimensions W  
x H x D  
13-1/8” x 14-11/16” x 2-11/16”  
(308 x 373 x 68mm)  
Weight  
75 lbs (34kg)  
Capacity  
INTRODUCTION  
The installation process involves three key steps, as  
follows:  
Select mounting configuration  
100mm x 100mm Centris mounting (flush  
and recessed)  
200mm x 100mm Centris mounting with  
interface adapter  
the interface adapter that accommodates two  
mounting hole patterns: 400mm x 200mm  
and 550 x 235mm  
TOOLS REQUIRED FOR INSTALLATION  
Connect cables  
Make adjustments  
Electric drill and bit set  
Hex wrench set  
Phillips screwdriver  
Level  
NOTE: Other tools may be required depending on the  
mounting surface and method of installation.  
3
 
Model MSP-DCCMD  
Installation Instructions  
PARTS  
Centris Interface  
(see notes)  
Set Screw  
(see notes)  
130  
140  
20  
30  
40  
50  
60  
70  
150  
160  
80  
90  
100  
110  
120  
170  
180  
190  
Figure 1: JWD PARTS  
4
 
Installation Instructions  
Model MSP-DCCMD  
PARTS (Continued)  
Table 2 below provides a list of the JWD parts.  
Table 2: JWD Parts  
ITEM  
DESCRIPTION  
QTY  
USED WITH NOTES  
NUMBER  
10  
20  
30  
40  
50  
60  
JWD MOUNT  
1
2
6
4
4
4
3/8” x 3” LAG SCREWS  
USE WITH 150  
PHILLIPS PAN HEAD MACHINE SCREW, M6 x 20mm  
PHILLIPS PAN HEAD MACHINE SCREW, M4 x 30mm  
PHILLIPS PAN HEAD MACHINE SCREW, M4 x 20mm  
PHILLIPS PAN HEAD MACHINE SCREW, M4 x 12mm  
USE WITH 110 AND 120£  
USE WITH 100*  
USE WITH 110**  
USE WITH  
CENTRIS INTERFACE‡  
70  
PHILLIPS PAN HEAD MACHINE SCREW, M4 x 8mm  
PHILLIPS FLAT HEAD MACHINE SCREW, M4 x 16mm  
PHILLIPS FLAT HEAD MACHINE SCREW, 8-32 x 3/8”  
3/4” THICK NYLON SPACER  
4
6
4
4
4
6
USE WITH 140  
USE WITH 140***  
USE WITH 160  
USE WITH 40*  
USE WITH 50**  
USE WITH 30  
80  
90  
100  
110  
120  
3/8” THICK NYLON SPACER  
5/16” THICK NYLON RETAINING SPACER  
(.75 Outside Diameter)  
130  
INTERFACE ADAPTER (400mm x 200mm and  
550mm x 235mm  
1
USE WITH 30 AND 120  
140  
150  
160  
170  
180  
190  
200mm x 100mm INTERFACE ADAPTER  
WALL BRACKET  
1
1
2
1
1
6
USE WITH 70 AND 80  
USE WITH 20  
COVER PLATE  
USE WITH 90  
3/16” HEX KEY  
FOR JOINTS  
5/32” HEX KEY  
FOR SET SCREW  
USE WITH 80  
1/8” NYLON SPACER  
NOTES:  
‡The M4 x 12mm screws (60) are used on the Centris interface for flush mount applications.  
*The M4 x 30mm screws (40) with spacers (100) are for recessed mount applications.  
**M4 x 20mm screws (50) with spacers (110) are for recessed mount applications.  
***The six M4 x 16mm screws (80) and six spacers (190) are used to attach the interface adapter (140) to the  
display.  
£The M6 x 20mm screws (30) are used with spacers (120) and the interface adapter (130).  
‡The M4 x 8mm screws (70) are also used to attach the Centris interface to the interface adapter (140).  
5
 
Model MSP-DCCMD  
Installation Instructions  
WALL BRACKET INSTALLATION  
Secure Wall Bracket  
Wood  
Stud  
WARNING: It is the responsibility of the installer to  
verify that the surface to which the mount is anchored  
will safely support the combined load of all attached  
components and equipment.  
150  
20  
To install the mount:  
1. Determine the exact mounting location prior to  
installation, considering the unit’s swing and  
extension radius.  
1/4" Pilot  
Holes  
2. Using the wall bracket (150) as a template, mark the  
two pilot holes for mounting the wall bracket.  
3. Drill two 1/4” pilot holes a minimum depth of 2” into the  
wood stud.  
Figure 2: Secure Wall Bracket  
NOTE: Make sure the wall bracket is level before  
installing the lag bolts.  
4. Using a 9/16” socket wrench, install two lag bolts (20)  
to secure the wall bracket (150) to the wall. Do not  
overtighten the lag bolts.  
IMPORTANT ! : Overtightening lag bolts may cause  
bracket to compress into soft wall surface, resulting in  
difficult mount installation or improper engaging of set  
screw in step 2 below. If this occurs, remove bracket,  
install 3/8" steel washers as required between bracket  
and wall surface, and reinstall bracket.  
10  
150  
NOTE:  
For a flush mount application, perform the “Attach  
Mount to Wall Bracket” on page 6 and then  
perform the “Flush Mount Centris Bracket to  
Display” on page 7.  
For a recessed mounting application, omit the  
procedure to “Attach Mount to Wall Bracket” on  
page 6 and proceed to the “Recess Mount Centris  
Bracket to Display” on page 7.  
Attach Mount to Wall Bracket  
1. Align the top of the mount (10) with the top of the wall  
bracket (150). Push the bottom of the mount against  
the bottom of the wall bracket until the mount fits  
snugly in place (see Figure 3).  
2. Using the 5/32” hex wrench (180), secure the mount  
to the wall bracket by tightening the set screw  
(see figure 3). Ensure set screw engages back side  
of bracket to properly secure mount.  
Set Screw  
180  
Figure 3: Attach Mount to Wall Bracket  
6
 
   
Installation Instructions  
Model MSP-DCCMD  
INSTALLATION (100mm x 100mm)  
Flush Mount Centris Bracket to Display  
Centris Bracket  
60  
1. Install two M4 x 12mm screws (60) into the top  
mounting holes (not shown) on the display .  
2. Align the mounting holes on the Centris bracket with  
the screws installed on the display. Hang the display  
on the Centris bracket. (see figure 4)  
3. Install two remaining M4 x 12mm screws (60) into the  
bottom mounting holes on the display.  
Recess Mount Centris Bracket to Display  
Use one of the following screw and spacer combinations:  
(40 with 100) or (50 with 110).  
Display  
CAUTION: If your display uses a screw size other  
thanM4 x 20mm or M4 x 30mm, DO NOT use the M4 x  
20mm or M4 x 30mm screws. Using the wrong screws  
could result in damage to your display.  
Figure 4: Flush Mount Centris Bracket to Display  
1. Select four M4 screws (40 or 50) and four retaining  
spacers (100 or 110) from parts bag.  
2. Place display face down on a clean dry surface.  
40 or 50  
3. Install four M4 screws (40 or 50) into the four  
mounting holes on centris bracket.(see figure 6)  
4. Slide 4 retaining spacers (100 or 110) onto four M4  
screws (40 or 50).  
100 or 110  
5. Align centris bracket, with screws (40 or 50) and  
spacers (100 or 110), with mounting holes in display  
back.  
6. Tighten all screws.  
Figure 5: Recess Mount Centris Bracket to Display  
7
 
 
Model MSP-DCCMD  
Installation Instructions  
INSTALLATION (200mm x 100MM)  
Attach Interface Adapter to Display  
1. Select six M4 screws (80) and six spacers (190) from  
parts bag.  
140  
80  
190  
2. Place display face down on a clean dry surface.  
3. Install six M4 screws (80) into the six mounting holes  
on the interface bracket (140). (see figure 8)  
4. Slide six retaining spacers (190) onto six M4 screws  
(80).  
NOTE: The arrow on the interface bracket (140) must  
point toward the top of the display.  
5. Align interface bracket (140), with screws (80) and  
spacers (190), with mounting holes in display back.  
6. Tighten all screws.  
Figure 6: Attach Interface Breacket to Display  
Attach Display to Centris Bracket  
1. Start two M4 x 8mm Phillips pan head screws (70) into  
the top two mounting holes of the previously attached  
interface bracket. (see figure 7)  
Centris Bracket  
70  
2. Hang the mount from the two screws started in Step 1.  
3. Install the remaining two M4 x 8mm Phillips pan head  
screws (70) into the bottom two mounting holes of the  
display.  
4. Secure the display to the mount (Centris bracket) by  
tightening all four M4 x 8mm Phillips pan head screws  
Display  
Figure 7: Attach Diaplay to Centris Bracket  
8
 
   
Installation Instructions  
Model MSP-DCCMD  
INSTALLATION (400mm x 200MM and  
550mm x 235MM)  
Arrow must  
point to top of  
display  
30  
130  
Attach 400mm x 200mm Interface Adapter  
NOTE: Used for 400mm x 200mm hole patterns.  
1. Select six M6 screws (30) and six spacers (120) from  
parts bag.  
2. Place display face down on a clean dry surface.  
120  
3. Install six M6 screws (30) into the six mounting holes  
on the interface bracket (130). (see figure 8)  
4. Slide six retaining spacers (120) onto six M6 screws  
(90).  
NOTE: The arrow on the interface bracket (130) must  
point toward the top of the display.  
5. Align interface bracket (130), with screws (30) and  
spacers (120), with mounting holes in display back.  
Figure 8: Attach 400mm x 200mm Interface Adapter  
6. Tighten all screws.  
Arrow must  
point to top of  
display  
30  
130  
Attach 550mm x 235mm Interface Adapter  
NOTE: Used for 550mm x 235mm hole patterns.  
1. Select four M6 screws (30) and four spacers (120)  
from parts bag.  
2. Place display face down on a clean dry surface.  
120  
3. Install four M6 screws (30) into the four mounting  
holes on the interface bracket (130). (see figure 9)  
4. Slide 4 retaining spacers (120) onto four M6 screws  
(30).  
NOTE: The arrow on the interface bracket (80) must  
point toward the top of the display.  
Display  
5. Align interface bracket (130), with screws (30) and  
spacers (120), with mounting holes in display back.  
Figure 9: Attach 550mm x 235mm Interface Adapter  
6. Tighten all screws.  
70  
Centris Bracket  
Attach Display to Centris Bracket  
1. Start two M4 x 5mm Phillips pan head screws (70) into  
the top two mounting holes of the previously attached  
interface bracket. (see figure 10)  
2. Hang the mount from the two screws started in Step 1.  
3. Install the remaining two M4 x 5mm Phillips pan head  
screws (70) into the bottom mounting holes of the  
display.  
70  
4. Secure the display to the mount (Centris bracket) by  
tightening all four M4 x 5mm Phillips pan head screws  
Display  
Figure 10: Attach Display to Centris Bracket  
9
 
     
Model MSP-DCCMD  
Installation Instructions  
CABLE MANAGEMENT  
Lateral Tension  
Adjustment Bolts  
WARNING: Make sure your cables do not run through  
a pinch point.  
1. Connect and secure power/audio/video cables,  
making sure to leave sufficient slack to allow for  
movement of the display.  
2. Route power/audio/video cables under each arm,  
allowing sufficient slack in cables for extension and  
avoiding pinch points.  
3. Secure cables using two cover plates (160) and four  
ADJUSTMENTS  
LATERAL TENSION ADJUSTMENT  
CAUTION: Overtightening adjustment will cause  
excessive wear.  
Figure 12: Adjust Lateral Tension  
1. Using a 3/16” hex wrench (170), slightly tighten or  
loosen lateral tension adjustment bolts.  
2. Check for desired tension.  
3. Repeat Steps 1 and 2 until desired tension is  
obtained.  
PITCH ADJUSTMENT  
CAUTION: Overtightening adjustment screw will  
cause excessive wear.  
NOTE: Remove display to make pitch adjustment.  
1. Check adjustment screw on the Centris interface to  
ensure that the screw is tight. (see figure 13)  
Pitch Tension  
Adjustment Screw  
2. If needed, use a 3/16” hex wrench (170) to tighten the  
screw.  
Figure 13: Pitch Adjustment  
160  
90  
Figure 11: Cable Management  
10  
 
     

Bernard Welder CA 15 User Manual
Black Box TV Video Accessories 3D HDMI Fiber Extender User Manual
Black Decker Sander 90556294 User Manual
Blanco Indoor Furnishings 441024 User Manual
Bose Indoor Furnishings UB20 Silver Ea User Manual
Boston Acoustics Speaker ASW 250 User Manual
Bowers Wilkins Speaker CWM LCR8 User Manual
Bravetti Cooktop MC665H User Manual
Broan Ventilation Hood L300KMG User Manual
Brother Network Card NC8100H User Manual