I N S T A L L A T I O N I N S T R U C T I O N S
Instrucciones de instalación
Installationsanleitung
Istruzioni di installazione
Installatie-instructies
Instruções de Instalação
Instructions d´installation
F-Series Steel Stud Installation Kit
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
FSA1018
Installation Instructions
FSA1018
TOOLS REQUIRED FOR INSTALLATION AND PARTS
(3/16")
1/2" (Ø13mm)
I/M
x1
A (1)
B (1)
C (1)
D (1)
J (4)
E (1)
F (1)
K (3)
L (3)
(1/4"-20)
G (1)
(1/4"-20 X 1 3/4")
M (3)
(1/4"-20 SNAPTOGGLE BB)
H (1)
(1/4"-20)
N (1)
(3/16")
3
FSA1018
Installation Instructions
Site Requirements
WARNING: IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! The figure below identifies the minimum reguirements for installation of display mounts onto a
steel stud structure. If the structure or its components do not meet these requirements contact the mount manufacturer for specific
instructions before attempting installation. It should also be noted that no other equipment should be mounted to the same stud.
Display Mount Installation Location
(Must be centered on stud)
If back side of wall is unfinished, drywall must be installed
to a minimum of one stud left and right of the stud(s)
being used to install the mount. Drywall must be
secured to studs with screws 12" on center
There must be a minimum of
1 7/8" (48mm) clearance
inside wall
FRONT
Drywall
1/2" minimum
Drywall Thickness
(Both Sides of Stud)
Steel Stud (2 x 4 / 25ga minimum)
Stud type and structural strength must conform to the North American
Specification for the Design of Cold-Formed Steel Structural Members
[362 S 125 18, C-Shaped, S-Stud Section]
Figure 1
4
Installation Instructions
FSA1018
NOTE: Wall plate and hardware removed is not required
for steel stud installation. It may be discarded or
kept for future use in a non-steel stud application.
Preparation of Existing Mount
If mount has previously been installed:
1. Remove display from mount following instructions provided
with mount.
2. Remove mount from wall following instructions provided
with mount.
Assemble Swing Arm to Steel Stud Wall Plate
To assemble the mount:
3. Proceed to step 4.
1. Orient swing arm so that it is positioned in front of mounting
tabs on wall plate (A). (See Figure 3)
2. Slide inner stud (C) up into bottom of swing arm.
3. Place spacer (G) up against bottom of swing arm and hold
spacer (G)and inner stud (C) in place. (See Figure 3)
4. Slide swingarm with inner stud (C) and spacer (G) between
mounting tabs in wall plate (A). (See Figure 3)
If mount has not previously been installed:
4. Remove mount wall plate from swing arm assembly by
removing screw, washers and spacers, pivot pin and
locknut. (See Figure 2)
5. Slide stepped spacer(D), spacer (E) and washer (F) onto
flat head cap screw (B). (See Figure 3)
6. Slide flat head capscrew (B) with spacers (E) and washer
(F) down into swing arm and through inner stud (C) and
lower spacer (G). (See Figure 3)
Screw
Swing Arm
Washers
7. Secure swing arm to mount using Nylock nut (H). (See
Figure 3)
Spacer
Pivot Pin
Existing Wall Plate
Locknut
Figure 2
(B) x1
(A) x1
(D) x1
(E) x1
(F) x1
(H) x1
Swing Arm
(C) x1
(G) x1
Figure 3
5
FSA1018
Installation Instructions
Mount Installation
After determining the site meets the installation requirements:
Drywall
1. Identify desired mounting location on wall.
2. Using a stud finder or similar method locate studs.
3. Align mounting holes in mount with studs making sure
mounting holes are centered on studs.
Plastic Straps
4. Mark location of three mounting holes on wall.
(See Figure 4)
5. Drill three 1/2" (Ø13mm) holes. (See Figure 4)
1/2" (Ø13mm) x3
(M) x3
Figure 5
5
7. Holding plastic straps on anchor (M), pull anchor away from
wall until channel rests flush behind wall making sure
anchor channel is positioned vertically on stud as show in
figues below. (See Figure 6)
8. Slide plastic cap on anchor (M) towards wall until flange of
cap is flush with wall. (See Figure 6)
Steel Stud
Drywall
Plastic Cap
(A) x1
(M) x3
Anchor Metal Channel
Mounting holes
centered on
studs
SIDE VIEW
Figure 6
Figure 4
9. Snap off plastic straps on anchor at wall by pushing side to
side, snapping off straps level with flange of plastic cap.
(See Figure 7)
6. Hold metal channel on anchor (M) flat alongside plastic
strapsandslidechannelthroughhole.(SeeFigure5)
10. Repeat steps 6 through 9 for each mounting hole.
6
Installation Instructions
FSA1018
Steel Stud
Drywall
Plastic Cap
Plastic Straps
Anchor Metal Channel
SIDE VIEW
Figure 7
11. Place mount over anchors and align mounting holes in
display mount with holes in anchors. (See Figure 8)
12. Place flat washer (K) onto button head capscrew (L).
13. Insert Phillips pan head capscrews (L) with flat washer (K)
through mounting hole in display mount and into anchor (M)
and tighten until flush against mount. DO NOT overtighten!
WARNING: IMPROPER INSTALLATION CAN LEAD TO
EQUIPMENT FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Overtightening of
mounting hardware can damage the steel studs. DO NOT
overtighten mounting hardware!
Steel Stud
Drywall
(K) x 3
(L) x 3
Display Mount
Anchor Metal Channel
SIDE VIEW
Figure 8
7
FSA1018
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
Chief Manufacturing, a division of
Milestone AV Technologies, Inc.
+31 (0)40 2668615
Asia Pacific
A
Room 24F, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA.
8804-000347 RevC
¤2008 Milestone AV Technologies
06/08
P
F
+86-755-8996 9226
+86-755-8996 9217
|